Master MPS
Power Range: 10 - 200 kVA

FEATURES

  • Smart Online UPS
  • Output Power Factor 90%
  • Efficiency Control System (ECS)
  • Robust and Reliable
  • Galvanic Isolation
  • Parallelable up to 8 Units
  • High Overload Capacity
  • Extensive Parallel Configurations
MODELSMPM 10BATMPM 15BATMPM 20BATMPM 30MPM 40MPM 60MPM 80MPM 100
INPUT 
Rated Voltage [V]380 / 400 / 415 three-phase + N
Voltage tolerance [V]400 ±20% - 25% @ full load1
Frequency [Hz]45-65
Soft start0 - 100% in 120 sec. (selectable)
Permitted frequency tolerance±2% (selectable from ±1% to ±5% from front panel)
Standard equipment providedBack Feed protection; separable bypass line
BYPASS 
Rated Voltage [V]220 / 230 / 240 single-phase + N
Rated frequency [Hz]50 or 60 (selectable)
OUTPUT 
Nominal power [kVA]10152030406080100
Active power [kW]913,5182736547290
Number of phases1
Rated voltage [V]220 / 230 / 240 single-phase + N (selectable)
Static stability±1%
Dynamic stability±5% in 10 msec.
Voltage distortion<1% with linear load / ≤3% with non-linear load
Crest factor [lpeack/irms]3:1
Frequency stability on battery0,05%
Frequency [Hz]50 or 60 (selectable)
Overload110% for 60 min; 125% for 10 min; 150% for 1 min.
BATTERIES 
TypeVRLA AGM / GEL; NiCd; SuperCaps; Li-ion; Flywheels
Residual ripple voltage<1%
Recharge voltage compensation-0,11% x V x °C
Typical charge current0,2 x C10
OVERALL SPECIFICATIONS 
Weight without batteries [kg]200220230255302416616665
Dimensions (WxDxH) [mm]555x740x1400800x740x1400800x800x1900
Remote signalsdry contacts
Remote controlsESD and bypass
CommunicationsDouble RS232 + dry contacts + 2 slots for communications interface
Ambient temperature for the UPS0 °C - +40 °C
Recommended temperature for battery life+20 °C - +25 °C
Range of relative humidity5-95% non-condensing
ColourDark grey RAL 7016
Noise level at 1 m (ECO Mode) [dBA]6062
IP ratingIP20
ECO Mode efficiencyup to 98%
StandardsEuropean directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
Classification in accordance with IEC 62040-3(Voltage Frequency Independent) VFI - SS - 111
Moving the UPSPallet jack

1 For wider tolerance conditions apply.
BATAlso available with internal batteries.

MODELSMPT 10BATMPT 15BATMPT 20BATMPT 30MPT 40MPT 60MPT 80
INPUT 
Rated Voltage [V]380 / 400 / 415 three-phase + N
Voltage tolerance [V]400 ±20% - 25% @ full load1
Frequency [Hz]45-65
Soft start0 - 100% in 120 sec. (selectable)
Permitted frequency tolerance±2% (selectable from ±1% to ±5% from front panel)
Standard equipment providedBack Feed protection; separable bypass line
BYPASS 
Rated Voltage [V]380 / 400 / 415 three-phase + N
Rated frequency [Hz]50 or 60 (selectable)
OUTPUT 
Nominal power [kVA]10152030406080
Active power [kW]913,51827365472
Number of phases3 + N
Rated voltage [V]380 / 400 / 415 three-phase + N (selectable)
Static stability±1%
Dynamic stability±5% in 10 msec.
Voltage distortion<1% with linear load / ≤3% with non-linear load
Crest factor [lpeack/irms]3:1
Frequency stability on battery0,05%
Frequency [Hz]50 or 60 (selectable)
Overload110% for 60 min; 125% for 10 min; 150% for 1 min.
BATTERIES 
TypeVRLA AGM / GEL; NiCd; SuperCaps; Li-ion; Flywheels
Residual ripple voltage<1%
Recharge voltage compensation-0,11% x V x °C
Typical charge current0,2 x C10
OVERALL SPECIFICATIONS 
Weight without batteries [kg]228241256315335460520
Dimensions (WxDxH) [mm]555x740x1400800x740x1400
Remote signalsdry contacts
Remote controlsESD and bypass
CommunicationsDouble RS232 + dry contacts + 2 slots for communications interface
Ambient temperature for the UPS0 °C - +40 °C
Recommended temperature for battery life+20 °C - +25 °C
Range of relative humidity5-95% non-condensing
ColourDark grey RAL 7016
Noise level at 1 m (ECO Mode) [dBA]6062
IP ratingIP20
ECO Mode efficiencyup to 98%
StandardsEuropean directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
Classification in accordance with IEC 62040-3(Voltage Frequency Independent) VFI - SS - 111
Moving the UPSPallet jack

1 For wider tolerance conditions apply.
BATAlso available with internal batteries.

MODELSMPT 100MPT 120MPT 160MPT 200
INPUT 
Rated Voltage [V]380 / 400 / 415 three-phase
Voltage tolerance [V]400 ±20% - 25% @ full load1
Frequency [Hz]45-65
Soft start0 - 100% in 120 sec. (selectable)
Permitted frequency tolerance±2% (selectable from ±1% to ±5% from front panel)
Standard equipment providedBack Feed protection; separable bypass line
BYPASS 
Rated Voltage [V]380 / 400 / 415 three-phase + N
Rated frequency [Hz]50 or 60 (selectable)
OUTPUT 
Nominal power [kVA]100120160200
Active power [kW]90108144180
Number of phases3 + N
Rated voltage [V]380 / 400 / 415 three-phase + N (selectable)
Static stability±1%
Dynamic stability±5% in 10 msec.
Voltage distortion<1% with linear load / ≤3% with non-linear load
Crest factor [lpeack/irms]3:1
Frequency stability on battery0,05%
Frequency [Hz]50 or 60 (selectable)
Overload110% for 60 min; 125% for 10 min; 150% for 1 min.
BATTERIES 
TypeVRLA AGM / GEL; NiCd; SuperCaps; Li-ion; Flywheels
Residual ripple voltage<1%
Recharge voltage compensation-0,11% x V x °C
Typical charge current0,2 x C10
OVERALL SPECIFICATIONS 
Weight without batteries [kg]620640700800
Dimensions (WxDxH) [mm]800x800x1900
Remote signalsdry contacts
Remote controlsESD and bypass
CommunicationsDouble RS232 + dry contacts + 2 slots for communications interface
Ambient temperature for the UPS0 °C - +40 °C
Recommended temperature for battery life+20 °C - +25 °C
Range of relative humidity5-95% non-condensing
ColourDark grey RAL 7016
Noise level at 1 m (ECO Mode) [dBA]6568
IP ratingIP20
ECO Mode efficiencyup to 98%
StandardsEuropean directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
Classification in accordance with IEC 62040-3(Voltage Frequency Independent) VFI - SS - 111
Moving the UPSPallet jack

1 For wider tolerance conditions apply.
BATAlso available with internal batteries.