UPS Riello Sentinel Pro
Power Range: 700 - 3000 VA
Power Range: 700 - 3000 VA
FEATURES
- Smart Online UPS
- Power Factor 0.9
- High Overload capability ( up to 150% )
- Wide Input Voltage ( 140 Volt - 276 Volt )
- Operating Flexibility
- Emergency Function
- Battery Optimisation
- Runtime expandability
- Low Noise Level
DESCRIPTION
UPS Riello tipe Sentinel Pro memiliki desain yang unik, modern, dan memiliki kinerja yang baik. Dengan menggunakan teknologi ON LINE double conversion yang menghasilkan tingkat performa yang baik untuk memberikan perlindungan maksimum terhapadap beban critical seperti server, data centre, dan peralatan elektronik lainnya.
UPS Riello tipe Sentinel Pro juga dilengkapi layar LCD yang dapat memberikan informasi voltase input dan output, status baterai, dan informasi status pengoperasian UPS. Sentinel Pro juga dilengkapi dengan port USB dan slot SNMP card.
Dapatkan Produk UPS Riello Asli dan Bergaransi Resmi, Hubungi Kami Untuk Layanan & Harga Terbaik !Â
Â
Technical Specifications
Â
| MODELS | SEP 700 | SEP 1000 | SEP 1000 ER | SEP 1500 | SEP 2200 | SEP 2200 ER | SEP 3000 | SEP 3000 ER |
|---|---|---|---|---|---|---|---|---|
| POWER | 700 VA / 630 W | 1000 VA / 900 W | 1500 VA / 1350 W | 2200 VA / 1980 W | 3000 VA / 2700 W | |||
| INPUT | Â | |||||||
| Rated Voltage [V] | 220 / 230 / 240 | |||||||
| Voltage range without battery intervention [V] | 140 < Vin < 276 @ 50% load / 184 < Vin < 276 @ 100% load | |||||||
| Voltage tolerance [V] | 230 ±20% | |||||||
| Maximum permitted voltage [V] | 300 | |||||||
| Rated frequency [Hz] | 50 / 60 | |||||||
| Frequency tolerance [Hz] | 50 ±5% / 60 ±5% | |||||||
| Power Factor | >0.99 | |||||||
| Current distortion | ≤7% | |||||||
| BYPASS | Â | |||||||
| Voltage tolerance [V] | 180 / 264 | |||||||
| Frequency tolerance [Hz] | Frequency selected (from ±1.5 to ±5 configurable) | |||||||
| Overload times | 125% for 5 s, 150% for 1s | |||||||
| OUTPUT | Â | |||||||
| Voltage distortion with linear load / with non-linear load | <2% / <4% | |||||||
| Frequency [Hz] | Selectable 50 or 60 or self-learning | |||||||
| Static variation | ±1% | |||||||
| Dynamic variation | ≤5% in 20 ms | |||||||
| Waveform | Sinusoidal | |||||||
| Current crest factor | 3:1 | |||||||
| Efficiency ECO and SMART ACTIVE Modes | 98% | |||||||
| BATTERIES | Â | |||||||
| Type | VRLA AGM maintenance-free lead based; Supercaps | |||||||
| Recharge time | 2-4 h | N.A. | 2-4 h | N.A. | 2-4 h | N.A. | ||
| OVERALL SPECIFICATIONS | Â | |||||||
| Net Weight [kg] | 10.9 | 13.3 | 7 | 14.8 | 25.6 | 14 | 28 | 15 |
| Gross Weight [kg] | 12.5 | 14.9 | 8.6 | 15.5 | 28.8 | 17 | 31.2 | 18 |
| Dimensions (WxDxH) [mm] | 158x422x235 | 190x446x333 | ||||||
| Packing dimensions (WxDxH) [mm] | 245x500x340 | 325x585x470 | ||||||
| Protection against overvoltage [J] | 300 | |||||||
| Protections | Overcurrent – short circuit – overvoltage – undervoltage – temperature – excessive low battery | |||||||
| Communications | USB / DB9 with RS232 and contacts / Slot for communications interface | |||||||
| Input plugs | 1x IEC 320 C14 (10 A) | 1x IEC 320 C20 (16 A) | ||||||
| Output sockets | 4x IEC 320 C13 (10 A) | 8x IEC 320 C13 (10 A) | 8x IEC 320 C13 (10 A) + 1x IEC 320 C19 (16 A) | |||||
| Standards | European directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111 UL 1778:2014 and CSA C22.2 No. 107.3-14 | |||||||
| Ambient temperature for the UPS | 0 °C – +40 °C | |||||||
| Recommended temperature for battery life | +20 °C – +25 °C | |||||||
| Range of relative humidity | 5-95% non-condensing | |||||||
| Colour | RAL 9005 | |||||||
| Noise level at 1m (ECO Mode) [dBA] | <40 | |||||||
| Standard equipment provided | Power cable, IEC-IEC cable, USB cable, safety manual, quick start guide | |||||||