UPS Riello Sentinel Dual SDU
Power Range: 4 - 10 kVA

FEATURES

  • Smart Online UPS
  • Output Power Factor = 1 ( start from SDU 5000 )
  • Parallelable up to 3 Units
  • High Quality Output Voltage
  • Selectable Output Voltage ( 220 / 230 / 240 V )
  • Dual Input Supplies Configuration ( SDU 10000 )
  • Total Microprocessor and DSP Control
  • Automatic Bypass Without Interruption
  • Simplified Installation
  • Operating Mode Selection

DESCRIPTION

UPS Riello tipe Sentinel Dual adalah solusi terbaik untuk memberikan perlindungan maksimal kepada peralatan elektrik yang penting seperti perangkat elektro-medis, data centre, server, alat telekomunikasi, dan lainnya.

UPS Riello tipe Sentinel Dual tersedia dalam kapasitas 4-10 kVA dengan teknologi ON LINE double conversion menjadikan UPS ini handal memberikan kelistrikan yang terbaik untuk peralatan elektronik anda karena listrik yang dihasilkan sudah disaring dan distabilkan baik untuk voltase maupun frekuensinya.

Dapatkan Produk UPS Riello Asli dan Bergaransi Resmi, Hubungi Kami Untuk Layanan & Harga Terbaik ! 

 

Technical Specifications
 
MODELS                             SDU 4000SDU 5000
SDU 5000
PDIST
SDU 6000
SDU 6000
PDIST
SDU 6000 ERSDU 8000SDU 10000SDU 10000 DISDU 10000 DI ER
INPUT 
Dual Inputnoyes
Rated Voltage [V]220 / 230 / 240
Voltage tolerance [V]230 ±20%
Minimum voltage [V]184
Rated frequency [Hz]50 / 60 ±5
Power factor>0,98
Current distortion≤2%
BYPASS 
Voltage tolerance [V]180 / 264 (selectable in ECO Mode or SMART ACTIVE Mode)
Frequency tolerance [Hz]Selected frequency ±5% (selectable by user)
Overload times<110% continuous, 130% for 1 h, 150% for 10 min, over 150% for 3 s
OUTPUT 
Nominal power [VA]40005000600060008000100001000010000
Active power [W]36005000600060008000100001000010000
Rated voltage [V]220 / 230 / 240 selectable
Voltge distortion<1% with linear load / <3% with non-linear load
Frequency [Hz]50 / 60 selectable
Static variation±1,5%
Dynamic variation≤5% in 20 ms
WaveformSinusoidal
Current crest factor [ipeak/irms]3:1
BATTERIES 
TypeVRLA AGM maintenance-free lead based
Recharge time4-6 h
OVERALL SPECIFICATIONS 
Net Weight [kg]3845462019+5320+6221
Gross Weight [kg]43535428839325
Dimensions (WxDxH) [mm]131x640x448 tower
19″x640x3U rack
2x (131x640x448) tower – 2x (19″x640x3U) rack
ER version(131x640x448) tower – (19″x640x3U) rack
Packing dimensions (WxDxH) [mm]800x600x(240+120)2x (800x600x240) + 120
ER version 800x600x(240+120)
Efficiencyup to 95% ON LINE Mode, 98% ECO Mode
ProtectionsOvercurrent – short circuit – overvoltage – undervoltage – temperature – excessive low battery
Parallel OperationnoOptional Parallel Card
CommunicationsUSB / RS232 / Slot for communications interface / R.E.P.O + Input contact
Input ConnectionTerminal board
Output socketsTerminal board + 2x IEC 320 C13 (10 A) + 1x IEC 320 C19 (16 A)Terminal board + 2x IEC 320 C19 (16 A)
PDIST: Terminal board + 8x IEC 320 C13 (10 A) + 2x IEC 320 C19 (16 A)
Terminal board + 2x IEC 320 C13 (10 A) + 3x IEC 320 C19 (16 A)
StandardsEuropean directives: LV 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111
Ambient temperature for the UPS0 °C – +40 °C
Recommended temperature for battery life+20 °C – +25 °C
Range of relative humidity5-95% non-condensing
ColourRAL 9005
Noise level at 1m (ECO Mode) [dBA]<48
Standard equipment providedUSB cable, handles kit